Generator set, Engine unit and spare parts

info@twinpower.cc

Cummins CCEC K50 Marine and Offshore Genset 60hz

Cummins CCEC K50 Marine and Offshore Genset 60hz

Cummins CCEC K50 Marine and Offshore Genset 60hz

Model:

CCFJ1150J-W~CCFJ1550J-W

Rated Power:

1150~1550kw

Frequency:

60Hz

Voltage:

220/380V, 240/416V, 254/440V, 266/460V, 277/480V

Application:

Marine Main Genset

Packing Size:

4450*1580*2380

Weight:

8800

HS Code:

850212

Technical Specification

Generator Set Specification

Model

CCFJ1150J-W~CCFJ1550J-W

Power

1150~1550kw

Frequency

60Hz

Voltage

220/380V, 240/416V, 254/440V, 266/460V, 277/480V

Emission

IMO1/IMO2

Marine Class Certificate

CCS, BV, ABS, LR, RS, etc.

Engine Specification

Engine Brand

Cummins

Engine Model

K50/ QSK50

Displacement

50L

Engine Type

16 Cylinders, V Type

Bore x Stroke

159*159

Cooling System

Seawater cooling/Radiator/Keel cooling

Alternator Specification

Alternator Brand

Stamford, Marathon, Leroy Somer, Siemens, Evotec, Kungfu, ect.

Alternator Protection class

IP23/IP44/IP54/IP55/IP65 Marine Class

Alternator Type

Brush-less, self-excited

Control System Specification

Controller Brand

Cummins, Weichai, ComAp, Enda, QILI, etc.

General Information

Genset Specification Frequency Engine Specification
Model kW kVA Hz Model Cyl.
CCFJ1150J-W 1150 1438 60 K50-DM 16
CCFJ1250J-W 1250 1562 K50-DM 16
CCFJ1350J-W 1350 1688 K50-DM 16
CCFJ1450J-W 1450 1812 QSK50-DM 16
CCFJ1550J-W 1550 1938 QSK50-DM 16
Overview

The Cummins CCEC K50 Marine and Offshore Genset 60Hz provides reliable high-capacity power for demanding marine and offshore applications. It supports large commercial vessels, offshore platforms, drilling support systems, and heavy-duty auxiliary power requirements. Built on the proven K50 engine platform, this genset delivers stable 60Hz output and supports continuous operation in challenging marine environments.

High-Power K50 Engine Performance

The K50 diesel engine delivers strong and consistent power across a wide range of load conditions. Its heavy-duty engine block and reinforced internal components support long running hours and smooth performance under high load. Efficient fuel injection improves combustion quality, which helps control fuel consumption while maintaining reliable 60Hz electrical output. This balance allows operators to meet high power demands with predictable operating costs.

Designed for Marine and Offshore Environments

The Cummins CCEC K50 genset uses marine-grade materials to protect key components from corrosion caused by salt air and high humidity. It manages vibration effectively, which helps extend component life in offshore conditions. In addition, the cooling and lubrication systems maintain stable operating temperatures during continuous duty, even in hot climates or confined engine rooms.

Easy Maintenance and Global Service Support

The genset layout allows easy access to routine service points such as filters and inspection areas. This design reduces maintenance time and supports efficient onboard servicing. Cummins also offers global service coverage, ensuring spare parts availability and technical support in major ports and offshore regions worldwide.

A Reliable High-Capacity Power Solution

With stable 60Hz output, strong load response, and durable construction, the Cummins CCEC K50 Marine and Offshore Genset suits operators who require dependable high-output power. Whether used as a main auxiliary unit or a backup power source, it delivers consistent performance, efficient operation, and long-term confidence for marine and offshore power generation.

Download of Cummins CCEC K50 Marine and Offshore Genset 60hz Datasheet

Model

Power

Engine Datasheet

Alternator Datasheet

Service Manual

Genset Drawing

CCFJ1150J-W~CCFJ1550J-W

1150~1550kw

Download

Download

Download

Download

Model

CCFJ1150J-W~CCFJ1550J-W

Power

1150~1550kw

Datasheet

Download

Parts Catalogue

Download

Service Manual

Download

Genset Datsheet

Download

Related Products

Cummins DCEC Marine Emergency Genset

Cummins CCEC K50 Marine Emergency Genset 50hz

Model: CCFJ1000Y-W/CCFJ1080Y-W

Rated Power: 1000~1080kw

Application: Marine Emergency Genset

HS Code: 850212

Cummins DCEC Marine Emergency Genset

Cummins CCEC K38 Marine Emergency Genset 50hz

Model: CCFJ500Y-W~CCFJ940Y-W

Rated Power: 500~940kw

Application: Marine Emergency Genset

HS Code: 850212

Cummins DCEC Marine Emergency Genset

Cummins CCEC K19 Marine Emergency Genset 50hz

Model: CCFJ300Y-W~CCFJ450Y-W

Rated Power: 300~450kw

Application: Marine Emergency Genset

Packing Size: 3550*1300*2350mm

HS Code: 850212

Cummins DCEC Marine Emergency Genset

Cummins CCEC N855 Marine Emergency Genset 50hz

Model: CCFJ200Y-W~CCFJ280Y-W

Rated Power: 200~280kw

Application: Marine Emergency Genset

Packing Size: 3020*1100*1750mm

HS Code: 850212

Ask For A Quick Quote

We will contact you within 1 working day, please pay attention to the email with the suffix “@twinpower.cc”. 

Thank you for reaching out!

We'll get back to you as soon as possible. For urgent matters, you’re welcome to contact us directly at info@twinpower.cc.