Generator set, Engine unit and spare parts

info@twinpower.cc

Cummins CCEC K50 1150KW-1250KW Marine Emergency Genset 60hz

Cummins DCEC Marine Emergency Genset

Cummins CCEC K50 1150KW-1250KW Marine Emergency Genset 60hz

Model:

CCFJ1150Y-W~CCFJ1250Y-W

Rated Power:

1150~1250kw

Frequency:

60Hz

Voltage:

220/380V, 240/416V, 254/440V, 266/460V, 277/480V

Application:

Marine Emergency Genset

Packing Size:

Weight:

HS Code:

850212

Technical Specification

Generator Set Specification

Model

CCFJ1150Y-W~CCFJ1250Y-W

Power

1150~1250kw

Frequency

60Hz

Voltage

220/380V, 240/416V, 254/440V, 266/460V, 277/480V

Emission

IMO1/IMO2

Marine Class Certificate

CCS, BV, ABS, LR, RS, etc.

Engine Specification

Engine Brand

Cummins

Engine Model

K50-DM

Displacement

50L

Engine Type

16 Cylinders, V Type

Bore x Stroke

159*159

Cooling System

Seawater cooling/Radiator/Keel cooling

Alternator Specification

Alternator Brand

Stamford, Marathon, Leroy Somer, Siemens, Evotec, Kungfu, ect.

Alternator Protection class

IP23/IP44/IP54/IP55/IP65 Marine Class

Alternator Type

Brush-less, self-excited

Control System Specification

Controller Brand

Cummins, Weichai, ComAp, Enda, QILI, etc.

General Information

Genset Specification Frequency Engine Specification
Model kW kVA Hz Model Cyl.
CCFJ1150Y-W 1150 1438 60 K50-DM 16
CCFJ1250Y-W 1250 1562 K50-DM 16
Overview

The Cummins CCEC K50 1150kW–1250kW Marine Emergency Genset 60Hz provides reliable emergency power for large marine vessels and offshore installations that require immediate electrical support during main power failure. It supports essential safety systems such as navigation, communication, emergency lighting, fire pumps, and vessel control equipment. Designed for ultra-high-capacity emergency duty, this genset helps ensure safety and operational stability in critical situations.

Rapid and Stable Emergency Power

Powered by the proven K50 diesel engine, this emergency genset starts quickly and delivers stable 60Hz output under sudden and heavy load conditions. The engine responds smoothly to rapid power demand, which allows critical systems to remain operational without interruption. Efficient combustion supports dependable performance while helping manage fuel consumption during extended emergency operation.

Built for Marine Emergency Conditions

The Cummins CCEC K50 emergency genset uses marine-grade materials to protect key components from corrosion caused by salt air and high humidity. Its heavy-duty structure supports stable operation under vessel vibration and motion. In addition, the cooling and lubrication systems maintain proper operating temperatures, which helps ensure reliable performance in confined emergency generator rooms.

Efficient Maintenance and Global Support

The genset layout allows easy access to routine service points, which supports regular testing and inspection required for emergency power systems. This design reduces maintenance time and simplifies onboard servicing. Cummins also provides global service coverage, ensuring spare parts availability and technical support in major ports and offshore regions worldwide.

An Ultra-High-Capacity Emergency Power Solution

With a power range from 1150kW to 1250kW, stable 60Hz output, and rapid starting capability, the Cummins CCEC K50 Marine Emergency Genset offers a dependable solution for ultra-high-capacity marine emergency power needs. It delivers consistent performance, strong reliability, and confidence for critical backup power on board.

Download of Cummins CCEC K50 1150KW-1250KW Marine Emergency Genset 60hz Datasheet

Model

Power

Engine Datasheet

Alternator Datasheet

Service Manual

Genset Drawing

CCFJ1150Y-W~CCFJ1250Y-W

1150~1250kw

Download

Download

Download

Download

Model

CCFJ1150Y-W~CCFJ1250Y-W

Power

1150~1250kw

Datasheet

Download

Parts Catalogue

Download

Service Manual

Download

Genset Datsheet

Download

Related Products

Cummins DCEC Marine Emergency Genset

Cummins CCEC K50 Marine Emergency Genset 50hz

Model: CCFJ1000Y-W/CCFJ1080Y-W

Rated Power: 1000~1080kw

Application: Marine Emergency Genset

HS Code: 850212

Cummins DCEC Marine Emergency Genset

Cummins CCEC K38 Marine Emergency Genset 50hz

Model: CCFJ500Y-W~CCFJ940Y-W

Rated Power: 500~940kw

Application: Marine Emergency Genset

HS Code: 850212

Cummins DCEC Marine Emergency Genset

Cummins CCEC K19 Marine Emergency Genset 50hz

Model: CCFJ300Y-W~CCFJ450Y-W

Rated Power: 300~450kw

Application: Marine Emergency Genset

Packing Size: 3550*1300*2350mm

HS Code: 850212

Cummins DCEC Marine Emergency Genset

Cummins CCEC N855 Marine Emergency Genset 50hz

Model: CCFJ200Y-W~CCFJ280Y-W

Rated Power: 200~280kw

Application: Marine Emergency Genset

Packing Size: 3020*1100*1750mm

HS Code: 850212

Ask For A Quick Quote

We will contact you within 1 working day, please pay attention to the email with the suffix “@twinpower.cc”. 

Thank you for reaching out!

We'll get back to you as soon as possible. For urgent matters, you’re welcome to contact us directly at info@twinpower.cc.